10m semi anechoic chambers

The main purpose of a 10m semi anechoic chamber is to perform full compliance measurements of radiated emission and immunity at 10m or 3m test distance. The combination of the pan-type 2mm galvanized panel system, parallel closing RF shielded doors and polystyrene hybrid absorbers on the walls, floor and ceiling creates a high performance controlled electromagnetic environment that complies with international immunity and emission test standards. The 10m semi anechoic chamber meets most EMC testing of commercial, military and automotive products.

The main purpose of a 10m semi anechoic chamber is to perform full compliance measurements of radiated emission and immunity at 10m or 3m test distance. The combination of the pan-type 2mm galvanized panel system, parallel closing RF shielded doors and polystyrene hybrid absorbers on the walls, floor and ceiling creates a high performance controlled electromagnetic environment that complies with international immunity and emission test standards. The 10m semi anechoic chamber meets most EMC testing of commercial, military and automotive products.

Features of a 10m semi anechoic chamber:

      Full compliance emission test site for frequency range of 30MHz to 18GHz as per CISPR 16-1-4 (2010) +annex A1 (2012) (free space testing)
Full compliance immunity test site for frequency range of 80MHz to 6GHz as per IEC/EN 61000-4-3
Shielding effectiveness according to EN 50147-1 (>80dB at 10kHz)

      Acceptance standards for a 10m semi anechoic chamber:
CISPR 16-1-4
IEC/EN 61000-4-3
EN 50147-1
ANSI C63.4
FCC part15
CISPR 25(special customization)
MIL-STD-461(special customization)

Product standards for a 10m semi anechoic chamber:
CISPR 32
CISPR 35
CISPR 11
CISPR 14
CISPR 15
CISPR 12
GB/T18387

      Typical performance of a 10m semi anechoic chamber:
NSA: +/-3.5dB at 10m test distance, +/-3.5dB at 3m test distance
sVSWR: ≤ 5.5dB at 3m test distanceFU: 75% of 16 points ≤ 6dB at 3m test distance & 1.5*1.5m test window (0.8m above floor level)

Typical specifications for a 10m semi anechoic chamber:

External dimensions

21.1mx13.9mx9.6mL*W*H

Dimensions

20.5mx13.3mx9.0mL*W*H

Control room dimensions

7.0mx4.0mx3.3mL*W*H

Amplifier room dimensions

4.0mx3.0mx3.3mL*W*H

Construction


2mm galvanized shielding panels with a free standing structural steel support

Absorbers

Hybrid solution of ferrite tiles and polystyrene hybrid absorber on walls,floor and ceiling

Ventilation

300mm*300mm/18GHz

Personal door

RF shielded door 0.9 m*2.1m (W*H)

Shielded door

RF shielded swing door 1.2m*2.1m (W*H)

Ground interface board

400mm*400mm/18GHz, including RF connectors

EUT power line

Filtered 220V 32A 50Hz/60Hz; 380V 63A 50Hz/60Hz

Lighting

Interference-free LED automatic lifting and lighting system

Frequency range

30MHz to 18Ghz for radiated emission and 80MHz to 6GHz for radiated immunity

Quiet zone size

5m ,Single axis (biaxial test required)

Positioning system

Optical fiber control turntable, turntable diameter 5m;

Optical fiber control antenna tower, 1-4m lifting.

In addition to the typical specifications of 10m semi anechoic chamber, RFT can also customize the anechoic chamber configuration for customers according to the size of quiet zone and the type of test standard.

10m semi anechoic chamber option

After special design of anechoic chamber, install turntable with integral dynamometer or external dynamometer for vehicle test, and the original performance of anechoic chamber would not be affected.

Quick Links:

Copyright © RuiFeng RF Technology (Shanghai) Co.,Ltd 沪ICP备2021035661号-1