The main purpose of CISPR-25 semi-anechoic chamber is to perform measurements of radiated emission or immunity specialized for vehicle on board equipment testing. The combination of the pan-type 2mm galvanized panel system, parallel closing RF shielded doors and polystyrene hybrid absorbers on the walls and ceiling eliminates unnecessary RF reflection and provides a high performance controlled electromagnetic environment that complies with international immunity and emission test standards, especially for automotive test standards, such as CISPR-25.
The main purpose of CISPR-25 semi-anechoic chamber is to perform measurements of radiated emission or immunity specialized for vehicle on board equipment testing. The combination of the pan-type 2mm galvanized panel system, parallel closing RF shielded doors and polystyrene hybrid absorbers on the walls and ceiling eliminates unnecessary RF reflection and provides a high performance controlled electromagnetic environment that complies with international immunity and emission test standards, especially for automotive test standards, such as CISPR-25.
Features of a CISPR-25 semi anechoic
chamber:
Noise floor level as per
CISPR-25 requirements
Grounded EUT test table as per
CISPR-25 design guide lines
Non-interference LED lights to meet the stringent requirements of
CISPR-25 noise floor level
Acceptance standards for a CISPR-25 semi
anechoic chamber:
CISPR 25
CISPR 12/en55012
ISO-11451
ISO-11452
SAE J551
Product standards for a
CISPR-25 semi anechoic chamber:
CISPR 25
Typical performance of a CISPR-25 semi anechoic chamber:
The minimum return loss of absorbers between 70MHz and 6GHz is 6dB. The model long wire antenna method (LWM) long line method is adopted to meet the new CISPR25 standard. The error between the actual test points of darkroom meeting more than 90% and the theoretical value of the model is not greater than ±6.0dB.
Typical specifications for a 10m semi anechoic chamber:
External dimensions |
6.7m*6.1m*4.2m(L*W*H) |
Dimensions |
6.1m*5.5m*3.6m(L*W*H) |
Construction
|
2mm galvanized shielding panels with a free standing structural steel support |
Absorbers |
Hybrid solution of ferrite tiles and polystyrene hybrid absorber on walls and ceiling |
Ventilation |
300mm*300mm/18GHz |
Shielded door |
RF shielded swing door 1.2m*2.1m (W*H) |
Ground interface board |
400mm*400mm/18GHz, including RF connectors |
EUT power line |
Filtered 220V 32A 50Hz/60Hz; 380V 63A 50Hz/60Hz |
Lighting |
No-interference LED lighting system |
Frequency range |
30MHz to 18Ghz for radiated emission and 80MHz to 6GHz for radiated immunity |
Test table |
A grounding system connected to the shielding is mounted on the test table surface. |
In addition to the typical specifications of CISPR-25 semi anechoic chamber, RFT can also customize the anechoic chamber configuration for customers’ requirements.
CISPR-25 semi anechoic chamber option
An additional shielding chamber can be installed to accommodate high power RF power amplifiers (amplifier room) or control and test equipment (control room).Copyright © RuiFeng RF Technology (Shanghai) Co.,Ltd 沪ICP备2021035661号-1