The main purpose of a 3m full anechoic chamber is to perform full compliance measurements of radiated emission and immunity at 3m test distance. The 3m full anechoic chamber is a multi-functional EMC test facility for commercial and telecom testing. The combination of the pan-type 2mm galvanized panel system, parallel closing RF shielded doors and polystyrene hybrid absorbers on the walls, floor and ceiling creates a high performance controlled electromagnetic environment that complies with international immunity and emission test standards.
The main purpose of a 3m full anechoic chamber is to perform full compliance measurements of radiated emission and immunity at 3m test distance. The 3m full anechoic chamber is a multi-functional EMC test facility for commercial and telecom testing. The combination of the pan-type 2mm galvanized panel system, parallel closing RF shielded doors and polystyrene hybrid absorbers on the walls, floor and ceiling creates a high performance controlled electromagnetic environment that complies with international immunity and emission test standards.
Features of a 3m full anechoic chamber:
Full compliance emission test
site for frequency range of 30MHz to 18GHz as per CISPR 16-1-4 (2010) +annex A1 (2012) (free space testing)
Full compliance immunity test
site for frequency range of 80MHz to 6GHz as per IEC/EN 61000-4-3
Shielding effectiveness
according to EN 50147-1 (>80dB at 10kHz)
Acceptance standards for a 3m full anechoic
chamber:
CISPR 16-1-4
IEC/EN 61000-4-3
EN 50147-1
ANSI C63.4
Product standards for a 3m
full anechoic chamber:
CISPR 32
CISPR 35
CISPR 11
CISPR 14
CISPR 15
Typical performance of a 3m full anechoic
chamber:
FSNSA: +/-3.5dB at 3m test distance
sVSWR: ≤ 5.5dB at 3m test distance
FU: 75% of 16 points ≤ 6dB at 3m test distance & 1.5*1.5m test window (0.8m
above floor level)
Typical specifications for a 3m full anechoic chamber:
External dimensions |
8.8m*5.8m*4.8m(L*W*H) |
Dimensions |
8.2m*5.2m*4.2m(L*W*H) |
Control room dimensions |
4.0m*4.0m*3.0m(L*W*H) |
Amplifier room dimensions |
4.0m*2.1m*3.0m(L*W*H) |
Construction
|
2mm galvanized shielding panels with a free standing structural steel support |
Absorbers |
Hybrid solution of ferrite tiles and polystyrene hybrid absorber on walls, floor and ceiling |
Ventilation |
300mm*300mm/18GHz |
Shielded door |
RF shielded swing door 1.2m*2.1m (W*H) |
Ground interface board |
400mm*400mm/18GHz, including RF connectors |
EUT power line |
Filtered 220V 32A 50Hz/60Hz; 380V 63A 50Hz/60Hz |
Lighting |
Interference-free LED automatic lifting and lighting system |
Frequency range |
30MHz to 18GHz for radiated emission and 80MHz to 6GHz for radiated immunity |
Quiet zone size |
Diameter 1.5m, height 1.5m |
Floor |
Ferrite tiles and hybrid absorbers incl. a walk way solution. |
Positioning system |
Optical fiber control turntable, turntable diameter 2m; Optical fiber control antenna tower, 1-3m lifting. |
Copyright © RuiFeng RF Technology (Shanghai) Co.,Ltd 沪ICP备2021035661号-1